Author

Jony Marcelo Zangari


Advisor

Claudio Melo


Date of publication

01/12/1998


Category

#Dissertations

Summary

Virtually every brazilian household refrigeration system (refrigerator or freezer) employs a concentric capillary tube suction line heat exchanger as the expansion device. The main purpose of this heat exchanger is to increase the mass flow rate through the capillary tube as well as the fluid temperature along the suction line. This work focuses on an experimental program envolving concentric heat exchangers and HFC-134a. [...]

Material for download

Access material

Know POSMEC

Learn more about one of the best post-graduate courses in mechanical engineering in Brazil

I want to know